Smith's Water Service & Installations, LLC.

Smith's Water Service & Installations, LLC.Smith's Water Service & Installations, LLC.Smith's Water Service & Installations, LLC.
Home
Services
City and Well Whole House
Reverse Osmosis
Service & Repair
Contact
Gallery
Hurricane Prep Guide
NELSON NR04-50 SPECS

Smith's Water Service & Installations, LLC.

Smith's Water Service & Installations, LLC.Smith's Water Service & Installations, LLC.Smith's Water Service & Installations, LLC.
Home
Services
City and Well Whole House
Reverse Osmosis
Service & Repair
Contact
Gallery
Hurricane Prep Guide
NELSON NR04-50 SPECS
More
  • Home
  • Services
  • City and Well Whole House
  • Reverse Osmosis
  • Service & Repair
  • Contact
  • Gallery
  • Hurricane Prep Guide
  • NELSON NR04-50 SPECS
  • Home
  • Services
  • City and Well Whole House
  • Reverse Osmosis
  • Service & Repair
  • Contact
  • Gallery
  • Hurricane Prep Guide
  • NELSON NR04-50 SPECS

Nelsen RO Sys 4-Stage, 50 gpd RO (NRO4-50)

 The Nelsen NRO4-50 is a 4-stage Reverse Osmosis (RO) system designed for residential drinking water applications. Here are the detailed specifications:


General:

  • System Type: 4-Stage Reverse Osmosis Drinking Water System
  • Manufacturer: Nelsen Corporation
  • Daily Flow Rate: 50 Gallons Per Day (GPD)
  • Application: Under-sink residential drinking water purification


Stages of Filtration:


  1. Stage 1: Sediment Pre-Filter
    • Function: Removes sediment, rust, dirt, and other solid debris.
    • Type: 5 Micron Polypropylene Sediment Cartridge Filter.
    • Housing: Clear pre-filter housing for visual inspection.

  1. Stage 2: Carbon Block Pre-Filter
    • Function: Removes chlorine, chloramines, VOCs, and other contaminants that cause bad taste and odor, protecting the RO membrane.
    • Type: Solid Block Carbon (e.g., 5 or 10 Micron Carbon Block).

  1. Stage 3: Reverse Osmosis Membrane
    • Function: The heart of the RO system. A semi-permeable membrane that rejects a high percentage (typically 95-98%) of dissolved solids, including lead, copper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, selenium, and other harmful contaminants.
    • Type: Thin Film Composite (TFC) membrane.
    • Capacity: 50 GPD.

  1. Stage 4: Post-Carbon Filter (Inline Granular Activated Carbon - GAC)
    • Function: Provides a final "polishing" of the water after it leaves the storage tank, removing any residual tastes or odors.
    • Type: Inline Granular Activated Carbon (GAC) cartridge.


System Components & Features:


  • Storage Tank: 3.2 Gallon NSF approved storage tank (typically white).
  • Fittings: Utilizes push-connect fittings for easy installation. Includes both 1/4" and 3/8" quick connect fittings (3/8" tubing often used for tank and faucet).
  • Faucet: Chrome long-reach, lead-free faucet.
  • Valves:
    • Automatic Shut-Off valve.
    • Angle Stop Adapter Valve for connecting to the cold water line.
    • Drain Saddle Valve for connection to the drain.


  • Included Accessories: Filter wrench for easy cartridge changes, all necessary tubing (e.g., yellow for production, red for waste, white for source).
  • Housings: Double O-ring housings for leak prevention.
  • Mounting: Typically mounted on a single bracket for compactness and ease of installation.


Operating Conditions (Recommended):


  • Minimum Water Pressure: 30 psi (some sources indicate 50 psi for optimal performance).
  • Maximum Water Pressure: 100 psi.
  • Maximum Water Operating Temperature: 40° - 100°F (4° - 38°C)
  • Recommended Max TDS (Total Dissolved Solids): <300 ppm (some sources state up to 2,000 ppm maximum, but lower TDS will result in better performance and membrane life).
  • Iron (Max): 0.3 ppm
  • Hardness (Max): <15 gpg (grains per gallon)
  • Hydrogen Sulfide: 0.0 ppm
  • Manganese (Max): <0.05 ppm
  • Turbidity (Max): <1 NTU
  • pH Range: 3-11


Dimensions (Approximate - Main Unit without tank):

  • "Footprint" space roughly 5" deep x 16" long x 18" high.
  • Storage tank is approximately 11" wide x 14" high.


Maintenance (General Guidelines):


  • Sediment & Carbon Pre-Filters (Stages 1 & 2): Recommended change every 6-12 months, or as needed based on water quality and usage.
  • RO Membrane (Stage 3): Recommended change every 24 months (2 years) or based on periodic TDS rejection tests.
  • Post-Carbon Filter (Stage 4): Recommended change every 6-12 months.

Warranty:

  • Components typically warranted for three years from installation (excluding membrane, pre & post filters).
  • Holding tank typically has a five-year warranty.

This information is compiled from various sources and represents typical specifications for the Nelsen NRO4-50 RO system. Specific details might vary slightly based on the exact model year or distributor. Always refer to the product's official user manual for the most accurate and up-to-date specifications.

Download

The Nelsen NRO4-50 is a 4-stage Reverse Osmosis (RO) system Specs (pdf)

Download